Motor power cables don’t just couple noise currents into adjacent cables: they inject unwanted noise currents into all conducting surfaces, including the machine frame. Machine-frame currents travel ...
Authored by: George Ellis, Chief Engineer, Servo Systems, Kollmorgen, Radford, Va. Key points: Three key measures — accuracy, response, and robust stability — characterize how servosystems perform.
One of the golden rules in wiring servomotors is to separate the power and feedback cables. Otherwise, power conductors near feedback conductors degrade data transmission by inducing noise in the form ...